MIL-PRF-5503G
a.
Examination (see 4.6.1).
b.
Immersion (see 4.6.3).
c.
Hydraulic properties (see 4.6.4).
d.
Proof pressure (see 4.6.7).
e.
Endurance (see 4.6.9).
f.
Burst pressure (see 4.6.10).
4.3 Conformance inspection. Conformance inspection shall consist of the following:
a. Individual tests (see 4.3.1).
b. Sampling tests (see 4.3.2).
4.3.1 Individual tests. Each actuator shall be subjected to the following tests:
a. Examination (see 4.6.1).
b. Leakage (see 4.6.6).
c. Proof pressure (see 4.6.8).
4.3.2 Sampling tests. Actuators shall be sampled according to ANSI/ASQ Z1.4 at the inspection
level (normal, tightened, or reduced) specified in the acquisition document (see 6.2).
4.4 Test conditions.
4.4.1 Test fluid. Unless otherwise specified by the associated specification, all first article tests
shall be performed with hydraulic fluid conforming to MIL-PRF-83282. Conformance tests
shall be conducted with hydraulic fluid conforming to MIL-PRF-87257, MIL-PRF-5606 or
MIL-PRF-83282.
4.4.2 Temperatures. Unless otherwise specified in the associated specification, the tests shall be
conducted at ambient temperatures between 50° and 110°F with hydraulic fluid temperatures
from 70° to 130°F.
4.5 Requirements cross-reference matrix. Table I provides a cross reference matrix of the
section 3 requirements tested or verified in the paragraphs below.