MIL-V-29592(AS)
4.5.2 Sampling tests. Samples shall be selected from each inspection lot
(see 4.5.2.1) in accordance with MIL-STD-105 using special inspection level S-1
with no rejects allowed. The sample automatic air vent valve shall be unpacked
and the inspections specified in 4.5.1, the rapid rate of pressure rise test
(4.7.5), and the oil expulsion test (4.7.8) shall be conducted.
TABLE I. First article tests
4.5.2.1 Inspection lot. For purposes of quality conformance inspection, a lot
shall be defined as all units of products manufactured under essentially
the same conditions and offered for acceptance at on time.